RRP from $556.50 (+GST)
Competitive Trade Pricing available to approved ABN holders
The EES70 Waste Treatment Controller is an economical, generic, replacement controller for a number of domestic waste treatment plants.
It provides all of the necessary functions for operation of the plant, plus additional functions to aid both the owner and operator/service person.
Domestic waste treatment plant manufacturers demand premium prices for replacement controllers, so the EES70 provides a more economical alternative to replacement and even often repair of the original controller.
Drop-in replacement for:
- Ozzi Kleen MkIII
- Ozzi Kleen MkIV
Suitable for upgrading (additional wiring modifications to the system required):
- Ozzi Kleen MkII
- Ozzi Kleen OK1
Features:
- Individual control of blower and pump
- Optional working level float switch input
- 12VDC outputs for solenoids and dosing pump
- Strobe and 2-wire remote alarm indicator outputs
- All 12V outputs protected against faults
- Air pressure switches for blower operation and high level sensing
- Easy to use LCD and keypad user interface
- Two different mounting options
- Compatible with Ozzi Kleen MkIII and MkIV remote alarm plates, and replacement remote alarm plates are also available.
Designed with the Service Agent in mind and supplied with a 12 month warranty.
Wholesale pricing is available to professional Service Agents – please contact us for further information.
Retail pricing:
- EES70 with mounting strips: $612.15 (GST inc)
- EES70 with standoff mounting brackets: $627.00 (GST inc)
- Remote alarm plate to suit EES70: $97.35 (GST inc)
Downloads:
Specifications:
Size (excluding mounts): | 230 x 222 x 90mm |
Weight: | 1850g |
IP rating: | IP51 (only valid when blower and pump are connected) |
Supply voltage: | 230VAC +/- 10%, 50Hz |
Power draw (controller only): | 30W Max |
Blower output: | 230VAC, 3A max current |
Pump output: | 230VAC, 5A max current |
Decant output: | 12VDC nominal. 350mA max current |
Sludge output: | 12VDC nominal. 400mA max current |
Dosing pump output: | 12VDC nominal. 350mA max current |
Strobe output: | 12VDC nominal. 250mA max current |
Remote alarm output: | 100bps asynchronous serial signal superimposed on 12VDC nominal. Current limited to 90mA. |
Float switch input | 12VDC into 1200Ω input impedance |